Interline 850 data sheet

Ra2425 d06 datasheets

International Interline 850 is a two component, chemically resistant, high solids, high build epoxy phenolic tank and pipe lining. Best Uses. International Interline 850 is formulated to provide corrosion protection for the internals of steel storage tanks and pipes containing a range of products, including crude oil, unleaded gasoline blends, MTBE, jet fuels, caustic solutions, potable water ... Safety Data Sheet GTA220 International Thinner-Eqpt Cleaner Version No. 5 Date Last Revised 09/05/12 Conforms to the requirements of Regulation (EC) No.1907/2006 (REACH), Annex II and Regulation (EC) No.1272/2008 SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1.
 

Red ribbon week 2019 coloring sheets

Interline 850 is typically specified as a two coat system at 5 mils (125 m) per coat to give a total coating system dry film thickness of 10 mils (250 microns). Exact specification for total dry film thickness will be dependent upon service end use requirements.
 

Online timesheets and expense reports

During storage and shipment, Interline 955 initiator must not be exposed to temperatures exceeding 30°C ( 90°F). Refrigeration recommended. STORAGE The information in this data sheet is not intended to be exhaustive; any person using the product for any purpose other than that specifically recommended in this data sheet without first Show this safety data sheet to the doctor in attendance. Eye contact Hold eye open and rinse slowly and gently with water for 15 - 20 minutes. Remove contact lenses, if present, after 5 minutes, then continue rinsing eye. Call a poison control center or doctor for treatment advice.

Interline 850 is typically specified as a two coat system at 125 microns (5 mils) per coat to give a total coating system dry film thickness of 250 microns (10 mils). Exact specification for total dry film thickness will be dependent upon service end use requirements. Interline 850 must only be installed when steel temperatures are above the minimum temperature indicated on the Interline 850 product data sheets. If heating is necessary to satisfy the lining specification, it should be by means of a heat exchange system incorporated into the dehumidified air supply, i.e. air admitted

Itunes fact sheet

Use it on tank exteriors, structural steel, piping, process equipment, bridges & water towers. Carbomastic 94 may also be used on barges, vessels and other marine applications. An optional micaceous iron oxide, (MIO), additive can be purchased separately and may be used per its Product Data Sheet to further enhance the coatings's performance.